X-Git-Url: http://cvs.zerfleddert.de/cgi-bin/gitweb.cgi/proxmark3-svn/blobdiff_plain/2487dfeb07edb8e08fa4ceadf187bcda87927455..38231ce012c278a912d587b567c02ce40e3df5e1:/client/cmdmain.c diff --git a/client/cmdmain.c b/client/cmdmain.c index 7bba80f4..843f9301 100644 --- a/client/cmdmain.c +++ b/client/cmdmain.c @@ -25,12 +25,14 @@ #include "cmdmain.h" #include "util.h" #include "cmdscript.h" +#include "cmdcrc.h" unsigned int current_command = CMD_UNKNOWN; static int CmdHelp(const char *Cmd); static int CmdQuit(const char *Cmd); +static int CmdRev(const char *Cmd); //For storing command that are received from the device #define CMD_BUFFER_SIZE 50 @@ -42,15 +44,16 @@ static int cmd_tail;//Starts as 0 static command_t CommandTable[] = { - {"help", CmdHelp, 1, "This help. Use ' help' for details of a particular command."}, - {"data", CmdData, 1, "{ Plot window / data buffer manipulation... }"}, - {"hf", CmdHF, 1, "{ High Frequency commands... }"}, - {"hw", CmdHW, 1, "{ Hardware commands... }"}, - {"lf", CmdLF, 1, "{ Low Frequency commands... }"}, - {"script", CmdScript, 1, "{ Scripting commands }"}, - {"quit", CmdQuit, 1, "Exit program"}, - {"exit", CmdQuit, 1, "Exit program"}, - {NULL, NULL, 0, NULL} + {"help", CmdHelp, 1, "This help. Use ' help' for details of a particular command."}, + {"data", CmdData, 1, "{ Plot window / data buffer manipulation... }"}, + {"hf", CmdHF, 1, "{ High Frequency commands... }"}, + {"hw", CmdHW, 1, "{ Hardware commands... }"}, + {"lf", CmdLF, 1, "{ Low Frequency commands... }"}, + {"reveng",CmdRev, 1, "Crc calculations from the software reveng1-30"}, + {"script",CmdScript,1, "{ Scripting commands }"}, + {"quit", CmdQuit, 1, "Exit program"}, + {"exit", CmdQuit, 1, "Exit program"}, + {NULL, NULL, 0, NULL} }; command_t* getTopLevelCommandTable() @@ -67,6 +70,13 @@ int CmdQuit(const char *Cmd) { return 99; } + +int CmdRev(const char *Cmd) +{ + CmdCrc(Cmd); + return 0; +} + /** * @brief This method should be called when sending a new command to the pm3. In case any old * responses from previous commands are stored in the buffer, a call to this method should clear them. @@ -177,10 +187,11 @@ void UsbCommandReceived(UsbCommand *UC) switch(UC->cmd) { // First check if we are handling a debug message case CMD_DEBUG_PRINT_STRING: { - char s[USB_CMD_DATA_SIZE+1] = {0x00}; + char s[USB_CMD_DATA_SIZE+1]; + memset(s, 0x00, sizeof(s)); size_t len = MIN(UC->arg[0],USB_CMD_DATA_SIZE); memcpy(s,UC->d.asBytes,len); - PrintAndLog("#db# %s ", s); + PrintAndLog("#db# %s", s); return; } break;