]>
cvs.zerfleddert.de Git - proxmark3-svn/blob - client/emv/apduinfo.c
1 //-----------------------------------------------------------------------------
2 // Copyright (C) 2017 Merlok
4 // This code is licensed to you under the terms of the GNU GPL, version 2 or,
5 // at your option, any later version. See the LICENSE.txt file for the text of
7 //-----------------------------------------------------------------------------
8 // APDU status bytes information
9 //-----------------------------------------------------------------------------
13 const APDUCode APDUCodeTable
[] = {
14 // ID Type Description
15 { "XXXX" , APDUCODE_TYPE_NONE
, "" }, // blank string
16 { "6---" , APDUCODE_TYPE_ERROR
, "Class not supported." },
17 { "61--" , APDUCODE_TYPE_INFO
, "Response bytes still available" },
18 { "61XX" , APDUCODE_TYPE_INFO
, "Command successfully executed; 'XX' bytes of data are available and can be requested using GET RESPONSE." },
19 { "62--" , APDUCODE_TYPE_WARNING
, "State of non-volatile memory unchanged" },
20 { "6200" , APDUCODE_TYPE_WARNING
, "No information given (NV-Ram not changed)" },
21 { "6201" , APDUCODE_TYPE_WARNING
, "NV-Ram not changed 1." },
22 { "6281" , APDUCODE_TYPE_WARNING
, "Part of returned data may be corrupted" },
23 { "6282" , APDUCODE_TYPE_WARNING
, "End of file/record reached before reading Le bytes" },
24 { "6283" , APDUCODE_TYPE_WARNING
, "Selected file invalidated" },
25 { "6284" , APDUCODE_TYPE_WARNING
, "Selected file is not valid. FCI not formated according to ISO" },
26 { "6285" , APDUCODE_TYPE_WARNING
, "No input data available from a sensor on the card. No Purse Engine enslaved for R3bc" },
27 { "62A2" , APDUCODE_TYPE_WARNING
, "Wrong R-MAC" },
28 { "62A4" , APDUCODE_TYPE_WARNING
, "Card locked (during reset( ))" },
29 { "62CX" , APDUCODE_TYPE_WARNING
, "Counter with value x (command dependent)" },
30 { "62F1" , APDUCODE_TYPE_WARNING
, "Wrong C-MAC" },
31 { "62F3" , APDUCODE_TYPE_WARNING
, "Internal reset" },
32 { "62F5" , APDUCODE_TYPE_WARNING
, "Default agent locked" },
33 { "62F7" , APDUCODE_TYPE_WARNING
, "Cardholder locked" },
34 { "62F8" , APDUCODE_TYPE_WARNING
, "Basement is current agent" },
35 { "62F9" , APDUCODE_TYPE_WARNING
, "CALC Key Set not unblocked" },
36 { "62FX" , APDUCODE_TYPE_WARNING
, "-" },
37 { "62XX" , APDUCODE_TYPE_WARNING
, "RFU" },
38 { "63--" , APDUCODE_TYPE_WARNING
, "State of non-volatile memory changed" },
39 { "6300" , APDUCODE_TYPE_WARNING
, "No information given (NV-Ram changed)" },
40 { "6381" , APDUCODE_TYPE_WARNING
, "File filled up by the last write. Loading/updating is not allowed." },
41 { "6382" , APDUCODE_TYPE_WARNING
, "Card key not supported." },
42 { "6383" , APDUCODE_TYPE_WARNING
, "Reader key not supported." },
43 { "6384" , APDUCODE_TYPE_WARNING
, "Plaintext transmission not supported." },
44 { "6385" , APDUCODE_TYPE_WARNING
, "Secured transmission not supported." },
45 { "6386" , APDUCODE_TYPE_WARNING
, "Volatile memory is not available." },
46 { "6387" , APDUCODE_TYPE_WARNING
, "Non-volatile memory is not available." },
47 { "6388" , APDUCODE_TYPE_WARNING
, "Key number not valid." },
48 { "6389" , APDUCODE_TYPE_WARNING
, "Key length is not correct." },
49 { "63C0" , APDUCODE_TYPE_WARNING
, "Verify fail, no try left." },
50 { "63C1" , APDUCODE_TYPE_WARNING
, "Verify fail, 1 try left." },
51 { "63C2" , APDUCODE_TYPE_WARNING
, "Verify fail, 2 tries left." },
52 { "63C3" , APDUCODE_TYPE_WARNING
, "Verify fail, 3 tries left." },
53 { "63CX" , APDUCODE_TYPE_WARNING
, "The counter has reached the value 'x' (0 = x = 15) (command dependent)." },
54 { "63F1" , APDUCODE_TYPE_WARNING
, "More data expected." },
55 { "63F2" , APDUCODE_TYPE_WARNING
, "More data expected and proactive command pending." },
56 { "63FX" , APDUCODE_TYPE_WARNING
, "-" },
57 { "63XX" , APDUCODE_TYPE_WARNING
, "RFU" },
58 { "64--" , APDUCODE_TYPE_ERROR
, "State of non-volatile memory unchanged" },
59 { "6400" , APDUCODE_TYPE_ERROR
, "No information given (NV-Ram not changed)" },
60 { "6401" , APDUCODE_TYPE_ERROR
, "Command timeout. Immediate response required by the card." },
61 { "64XX" , APDUCODE_TYPE_ERROR
, "RFU" },
62 { "65--" , APDUCODE_TYPE_ERROR
, "State of non-volatile memory changed" },
63 { "6500" , APDUCODE_TYPE_ERROR
, "No information given" },
64 { "6501" , APDUCODE_TYPE_ERROR
, "Write error. Memory failure. There have been problems in writing or reading the EEPROM. Other hardware problems may also bring this error." },
65 { "6581" , APDUCODE_TYPE_ERROR
, "Memory failure" },
66 { "65FX" , APDUCODE_TYPE_ERROR
, "-" },
67 { "65XX" , APDUCODE_TYPE_ERROR
, "RFU" },
68 { "66--" , APDUCODE_TYPE_SECURITY
, " " },
69 { "6600" , APDUCODE_TYPE_SECURITY
, "Error while receiving (timeout)" },
70 { "6601" , APDUCODE_TYPE_SECURITY
, "Error while receiving (character parity error)" },
71 { "6602" , APDUCODE_TYPE_SECURITY
, "Wrong checksum" },
72 { "6603" , APDUCODE_TYPE_SECURITY
, "The current DF file without FCI" },
73 { "6604" , APDUCODE_TYPE_SECURITY
, "No SF or KF under the current DF" },
74 { "6669" , APDUCODE_TYPE_SECURITY
, "Incorrect Encryption/Decryption Padding" },
75 { "66XX" , APDUCODE_TYPE_SECURITY
, "-" },
76 { "67--" , APDUCODE_TYPE_ERROR
, " " },
77 { "6700" , APDUCODE_TYPE_ERROR
, "Wrong length" },
78 { "67XX" , APDUCODE_TYPE_ERROR
, "length incorrect (procedure)(ISO 7816-3)" },
79 { "68--" , APDUCODE_TYPE_ERROR
, "Functions in CLA not supported" },
80 { "6800" , APDUCODE_TYPE_ERROR
, "No information given (The request function is not supported by the card)" },
81 { "6881" , APDUCODE_TYPE_ERROR
, "Logical channel not supported" },
82 { "6882" , APDUCODE_TYPE_ERROR
, "Secure messaging not supported" },
83 { "6883" , APDUCODE_TYPE_ERROR
, "Last command of the chain expected" },
84 { "6884" , APDUCODE_TYPE_ERROR
, "Command chaining not supported" },
85 { "68FX" , APDUCODE_TYPE_ERROR
, "-" },
86 { "68XX" , APDUCODE_TYPE_ERROR
, "RFU" },
87 { "69--" , APDUCODE_TYPE_ERROR
, "Command not allowed" },
88 { "6900" , APDUCODE_TYPE_ERROR
, "No information given (Command not allowed)" },
89 { "6901" , APDUCODE_TYPE_ERROR
, "Command not accepted (inactive state)" },
90 { "6981" , APDUCODE_TYPE_ERROR
, "Command incompatible with file structure" },
91 { "6982" , APDUCODE_TYPE_ERROR
, "Security condition not satisfied." },
92 { "6983" , APDUCODE_TYPE_ERROR
, "Authentication method blocked" },
93 { "6984" , APDUCODE_TYPE_ERROR
, "Referenced data reversibly blocked (invalidated)" },
94 { "6985" , APDUCODE_TYPE_ERROR
, "Conditions of use not satisfied." },
95 { "6986" , APDUCODE_TYPE_ERROR
, "Command not allowed (no current EF)" },
96 { "6987" , APDUCODE_TYPE_ERROR
, "Expected secure messaging (SM) object missing" },
97 { "6988" , APDUCODE_TYPE_ERROR
, "Incorrect secure messaging (SM) data object" },
98 { "698D" , APDUCODE_TYPE_NONE
, "Reserved" },
99 { "6996" , APDUCODE_TYPE_ERROR
, "Data must be updated again" },
100 { "69E1" , APDUCODE_TYPE_ERROR
, "POL1 of the currently Enabled Profile prevents this action." },
101 { "69F0" , APDUCODE_TYPE_ERROR
, "Permission Denied" },
102 { "69F1" , APDUCODE_TYPE_ERROR
, "Permission Denied - Missing Privilege" },
103 { "69FX" , APDUCODE_TYPE_ERROR
, "-" },
104 { "69XX" , APDUCODE_TYPE_ERROR
, "RFU" },
105 { "6A--" , APDUCODE_TYPE_ERROR
, "Wrong parameter(s) P1-P2" },
106 { "6A00" , APDUCODE_TYPE_ERROR
, "No information given (Bytes P1 and/or P2 are incorrect)" },
107 { "6A80" , APDUCODE_TYPE_ERROR
, "The parameters in the data field are incorrect." },
108 { "6A81" , APDUCODE_TYPE_ERROR
, "Function not supported" },
109 { "6A82" , APDUCODE_TYPE_ERROR
, "File not found" },
110 { "6A83" , APDUCODE_TYPE_ERROR
, "Record not found" },
111 { "6A84" , APDUCODE_TYPE_ERROR
, "There is insufficient memory space in record or file" },
112 { "6A85" , APDUCODE_TYPE_ERROR
, "Lc inconsistent with TLV structure" },
113 { "6A86" , APDUCODE_TYPE_ERROR
, "Incorrect P1 or P2 parameter." },
114 { "6A87" , APDUCODE_TYPE_ERROR
, "Lc inconsistent with P1-P2" },
115 { "6A88" , APDUCODE_TYPE_ERROR
, "Referenced data not found" },
116 { "6A89" , APDUCODE_TYPE_ERROR
, "File already exists" },
117 { "6A8A" , APDUCODE_TYPE_ERROR
, "DF name already exists." },
118 { "6AF0" , APDUCODE_TYPE_ERROR
, "Wrong parameter value" },
119 { "6AFX" , APDUCODE_TYPE_ERROR
, "-" },
120 { "6AXX" , APDUCODE_TYPE_ERROR
, "RFU" },
121 { "6B--" , APDUCODE_TYPE_ERROR
, " " },
122 { "6B00" , APDUCODE_TYPE_ERROR
, "Wrong parameter(s) P1-P2" },
123 { "6BXX" , APDUCODE_TYPE_ERROR
, "Reference incorrect (procedure byte), (ISO 7816-3)" },
124 { "6C--" , APDUCODE_TYPE_ERROR
, "Wrong length Le" },
125 { "6C00" , APDUCODE_TYPE_ERROR
, "Incorrect P3 length." },
126 { "6CXX" , APDUCODE_TYPE_ERROR
, "Bad length value in Le; 'xx' is the correct exact Le" },
127 { "6D--" , APDUCODE_TYPE_ERROR
, " " },
128 { "6D00" , APDUCODE_TYPE_ERROR
, "Instruction code not supported or invalid" },
129 { "6DXX" , APDUCODE_TYPE_ERROR
, "Instruction code not programmed or invalid (procedure byte), (ISO 7816-3)" },
130 { "6E--" , APDUCODE_TYPE_ERROR
, " " },
131 { "6E00" , APDUCODE_TYPE_ERROR
, "Class not supported" },
132 { "6EXX" , APDUCODE_TYPE_ERROR
, "Instruction class not supported (procedure byte), (ISO 7816-3)" },
133 { "6F--" , APDUCODE_TYPE_ERROR
, "Internal exception" },
134 { "6F00" , APDUCODE_TYPE_ERROR
, "Command aborted - more exact diagnosis not possible (e.g., operating system error)." },
135 { "6FFF" , APDUCODE_TYPE_ERROR
, "Card dead (overuse, \85 )" },
136 { "6FXX" , APDUCODE_TYPE_ERROR
, "No precise diagnosis (procedure byte), (ISO 7816-3)" },
137 { "9---" , APDUCODE_TYPE_NONE
, "" },
138 { "9000" , APDUCODE_TYPE_INFO
, "Command successfully executed (OK)." },
139 { "9004" , APDUCODE_TYPE_WARNING
, "PIN not succesfully verified, 3 or more PIN tries left" },
140 { "9008" , APDUCODE_TYPE_NONE
, "Key/file not found" },
141 { "9080" , APDUCODE_TYPE_WARNING
, "Unblock Try Counter has reached zero" },
142 { "9100" , APDUCODE_TYPE_NONE
, "OK" },
143 { "9101" , APDUCODE_TYPE_NONE
, "States.activity, States.lock Status or States.lockable has wrong value" },
144 { "9102" , APDUCODE_TYPE_NONE
, "Transaction number reached its limit" },
145 { "910C" , APDUCODE_TYPE_NONE
, "No changes" },
146 { "910E" , APDUCODE_TYPE_NONE
, "Insufficient NV-Memory to complete command" },
147 { "911C" , APDUCODE_TYPE_NONE
, "Command code not supported" },
148 { "911E" , APDUCODE_TYPE_NONE
, "CRC or MAC does not match data" },
149 { "9140" , APDUCODE_TYPE_NONE
, "Invalid key number specified" },
150 { "917E" , APDUCODE_TYPE_NONE
, "Length of command string invalid" },
151 { "919D" , APDUCODE_TYPE_NONE
, "Not allow the requested command" },
152 { "919E" , APDUCODE_TYPE_NONE
, "Value of the parameter invalid" },
153 { "91A0" , APDUCODE_TYPE_NONE
, "Requested AID not present on PICC" },
154 { "91A1" , APDUCODE_TYPE_NONE
, "Unrecoverable error within application" },
155 { "91AE" , APDUCODE_TYPE_NONE
, "Authentication status does not allow the requested command" },
156 { "91AF" , APDUCODE_TYPE_NONE
, "Additional data frame is expected to be sent" },
157 { "91BE" , APDUCODE_TYPE_NONE
, "Out of boundary" },
158 { "91C1" , APDUCODE_TYPE_NONE
, "Unrecoverable error within PICC" },
159 { "91CA" , APDUCODE_TYPE_NONE
, "Previous Command was not fully completed" },
160 { "91CD" , APDUCODE_TYPE_NONE
, "PICC was disabled by an unrecoverable error" },
161 { "91CE" , APDUCODE_TYPE_NONE
, "Number of Applications limited to 28" },
162 { "91DE" , APDUCODE_TYPE_NONE
, "File or application already exists" },
163 { "91EE" , APDUCODE_TYPE_NONE
, "Could not complete NV-write operation due to loss of power" },
164 { "91F0" , APDUCODE_TYPE_NONE
, "Specified file number does not exist" },
165 { "91F1" , APDUCODE_TYPE_NONE
, "Unrecoverable error within file" },
166 { "920x" , APDUCODE_TYPE_INFO
, "Writing to EEPROM successful after 'x' attempts." },
167 { "9210" , APDUCODE_TYPE_ERROR
, "Insufficient memory. No more storage available." },
168 { "9240" , APDUCODE_TYPE_ERROR
, "Writing to EEPROM not successful." },
169 { "9301" , APDUCODE_TYPE_NONE
, "Integrity error" },
170 { "9302" , APDUCODE_TYPE_NONE
, "Candidate S2 invalid" },
171 { "9303" , APDUCODE_TYPE_ERROR
, "Application is permanently locked" },
172 { "9400" , APDUCODE_TYPE_ERROR
, "No EF selected." },
173 { "9401" , APDUCODE_TYPE_NONE
, "Candidate currency code does not match purse currency" },
174 { "9402" , APDUCODE_TYPE_NONE
, "Candidate amount too high" },
175 { "9402" , APDUCODE_TYPE_ERROR
, "Address range exceeded." },
176 { "9403" , APDUCODE_TYPE_NONE
, "Candidate amount too low" },
177 { "9404" , APDUCODE_TYPE_ERROR
, "FID not found, record not found or comparison pattern not found." },
178 { "9405" , APDUCODE_TYPE_NONE
, "Problems in the data field" },
179 { "9406" , APDUCODE_TYPE_ERROR
, "Required MAC unavailable" },
180 { "9407" , APDUCODE_TYPE_NONE
, "Bad currency : purse engine has no slot with R3bc currency" },
181 { "9408" , APDUCODE_TYPE_NONE
, "R3bc currency not supported in purse engine" },
182 { "9408" , APDUCODE_TYPE_ERROR
, "Selected file type does not match command." },
183 { "9580" , APDUCODE_TYPE_NONE
, "Bad sequence" },
184 { "9681" , APDUCODE_TYPE_NONE
, "Slave not found" },
185 { "9700" , APDUCODE_TYPE_NONE
, "PIN blocked and Unblock Try Counter is 1 or 2" },
186 { "9702" , APDUCODE_TYPE_NONE
, "Main keys are blocked" },
187 { "9704" , APDUCODE_TYPE_NONE
, "PIN not succesfully verified, 3 or more PIN tries left" },
188 { "9784" , APDUCODE_TYPE_NONE
, "Base key" },
189 { "9785" , APDUCODE_TYPE_NONE
, "Limit exceeded - C-MAC key" },
190 { "9786" , APDUCODE_TYPE_NONE
, "SM error - Limit exceeded - R-MAC key" },
191 { "9787" , APDUCODE_TYPE_NONE
, "Limit exceeded - sequence counter" },
192 { "9788" , APDUCODE_TYPE_NONE
, "Limit exceeded - R-MAC length" },
193 { "9789" , APDUCODE_TYPE_NONE
, "Service not available" },
194 { "9802" , APDUCODE_TYPE_ERROR
, "No PIN defined." },
195 { "9804" , APDUCODE_TYPE_ERROR
, "Access conditions not satisfied, authentication failed." },
196 { "9835" , APDUCODE_TYPE_ERROR
, "ASK RANDOM or GIVE RANDOM not executed." },
197 { "9840" , APDUCODE_TYPE_ERROR
, "PIN verification not successful." },
198 { "9850" , APDUCODE_TYPE_ERROR
, "INCREASE or DECREASE could not be executed because a limit has been reached." },
199 { "9862" , APDUCODE_TYPE_ERROR
, "Authentication Error, application specific (incorrect MAC)" },
200 { "9900" , APDUCODE_TYPE_NONE
, "1 PIN try left" },
201 { "9904" , APDUCODE_TYPE_NONE
, "PIN not succesfully verified, 1 PIN try left" },
202 { "9985" , APDUCODE_TYPE_NONE
, "Wrong status - Cardholder lock" },
203 { "9986" , APDUCODE_TYPE_ERROR
, "Missing privilege" },
204 { "9987" , APDUCODE_TYPE_NONE
, "PIN is not installed" },
205 { "9988" , APDUCODE_TYPE_NONE
, "Wrong status - R-MAC state" },
206 { "9A00" , APDUCODE_TYPE_NONE
, "2 PIN try left" },
207 { "9A04" , APDUCODE_TYPE_NONE
, "PIN not succesfully verified, 2 PIN try left" },
208 { "9A71" , APDUCODE_TYPE_NONE
, "Wrong parameter value - Double agent AID" },
209 { "9A72" , APDUCODE_TYPE_NONE
, "Wrong parameter value - Double agent Type" },
210 { "9D05" , APDUCODE_TYPE_ERROR
, "Incorrect certificate type" },
211 { "9D07" , APDUCODE_TYPE_ERROR
, "Incorrect session data size" },
212 { "9D08" , APDUCODE_TYPE_ERROR
, "Incorrect DIR file record size" },
213 { "9D09" , APDUCODE_TYPE_ERROR
, "Incorrect FCI record size" },
214 { "9D0A" , APDUCODE_TYPE_ERROR
, "Incorrect code size" },
215 { "9D10" , APDUCODE_TYPE_ERROR
, "Insufficient memory to load application" },
216 { "9D11" , APDUCODE_TYPE_ERROR
, "Invalid AID" },
217 { "9D12" , APDUCODE_TYPE_ERROR
, "Duplicate AID" },
218 { "9D13" , APDUCODE_TYPE_ERROR
, "Application previously loaded" },
219 { "9D14" , APDUCODE_TYPE_ERROR
, "Application history list full" },
220 { "9D15" , APDUCODE_TYPE_ERROR
, "Application not open" },
221 { "9D17" , APDUCODE_TYPE_ERROR
, "Invalid offset" },
222 { "9D18" , APDUCODE_TYPE_ERROR
, "Application already loaded" },
223 { "9D19" , APDUCODE_TYPE_ERROR
, "Invalid certificate" },
224 { "9D1A" , APDUCODE_TYPE_ERROR
, "Invalid signature" },
225 { "9D1B" , APDUCODE_TYPE_ERROR
, "Invalid KTU" },
226 { "9D1D" , APDUCODE_TYPE_ERROR
, "MSM controls not set" },
227 { "9D1E" , APDUCODE_TYPE_ERROR
, "Application signature does not exist" },
228 { "9D1F" , APDUCODE_TYPE_ERROR
, "KTU does not exist" },
229 { "9D20" , APDUCODE_TYPE_ERROR
, "Application not loaded" },
230 { "9D21" , APDUCODE_TYPE_ERROR
, "Invalid Open command data length" },
231 { "9D30" , APDUCODE_TYPE_ERROR
, "Check data parameter is incorrect (invalid start address)" },
232 { "9D31" , APDUCODE_TYPE_ERROR
, "Check data parameter is incorrect (invalid length)" },
233 { "9D32" , APDUCODE_TYPE_ERROR
, "Check data parameter is incorrect (illegal memory check area)" },
234 { "9D40" , APDUCODE_TYPE_ERROR
, "Invalid MSM Controls ciphertext" },
235 { "9D41" , APDUCODE_TYPE_ERROR
, "MSM controls already set" },
236 { "9D42" , APDUCODE_TYPE_ERROR
, "Set MSM Controls data length less than 2 bytes" },
237 { "9D43" , APDUCODE_TYPE_ERROR
, "Invalid MSM Controls data length" },
238 { "9D44" , APDUCODE_TYPE_ERROR
, "Excess MSM Controls ciphertext" },
239 { "9D45" , APDUCODE_TYPE_ERROR
, "Verification of MSM Controls data failed" },
240 { "9D50" , APDUCODE_TYPE_ERROR
, "Invalid MCD Issuer production ID" },
241 { "9D51" , APDUCODE_TYPE_ERROR
, "Invalid MCD Issuer ID" },
242 { "9D52" , APDUCODE_TYPE_ERROR
, "Invalid set MSM controls data date" },
243 { "9D53" , APDUCODE_TYPE_ERROR
, "Invalid MCD number" },
244 { "9D54" , APDUCODE_TYPE_ERROR
, "Reserved field error" },
245 { "9D55" , APDUCODE_TYPE_ERROR
, "Reserved field error" },
246 { "9D56" , APDUCODE_TYPE_ERROR
, "Reserved field error" },
247 { "9D57" , APDUCODE_TYPE_ERROR
, "Reserved field error" },
248 { "9D60" , APDUCODE_TYPE_ERROR
, "MAC verification failed" },
249 { "9D61" , APDUCODE_TYPE_ERROR
, "Maximum number of unblocks reached" },
250 { "9D62" , APDUCODE_TYPE_ERROR
, "Card was not blocked" },
251 { "9D63" , APDUCODE_TYPE_ERROR
, "Crypto functions not available" },
252 { "9D64" , APDUCODE_TYPE_ERROR
, "No application loaded" },
253 { "9E00" , APDUCODE_TYPE_NONE
, "PIN not installed" },
254 { "9E04" , APDUCODE_TYPE_NONE
, "PIN not succesfully verified, PIN not installed" },
255 { "9F00" , APDUCODE_TYPE_NONE
, "PIN blocked and Unblock Try Counter is 3" },
256 { "9F04" , APDUCODE_TYPE_NONE
, "PIN not succesfully verified, PIN blocked and Unblock Try Counter is 3" },
257 { "9FXX" , APDUCODE_TYPE_NONE
, "Command successfully executed; 'xx' bytes of data are available and can be requested using GET RESPONSE." },
258 { "9xXX" , APDUCODE_TYPE_NONE
, "Application related status, (ISO 7816-3)" }
260 const size_t APDUCodeTableLen
= sizeof ( APDUCodeTable
)/ sizeof ( APDUCode
);
262 int CodeCmp ( const char * code1
, const char * code2
) {
265 for ( int i
= 0 ; i
< 4 ; i
++) {
266 if ( code1
[ i
] == code2
[ i
])
268 if ( code1
[ i
] == 'X' || code2
[ i
] == 'X' )
274 if ( cmp
+ xsymb
== 4 )
280 const APDUCode
* const GetAPDUCode ( uint8_t sw1
, uint8_t sw2
) {
286 sprintf (& buf
[ 0 ], "%02X " , sw1
);
287 sprintf (& buf
[ 2 ], "%02X " , sw2
);
289 for ( int i
= 0 ; i
< APDUCodeTableLen
; i
++) {
290 res
= CodeCmp ( APDUCodeTable
[ i
]. ID
, buf
);
294 return & APDUCodeTable
[ i
];
298 if ( res
> 0 && mineq
> res
) {
304 // if we have not equal, but with some 'X'
305 if ( mineqindx
< 100 ) {
306 return & APDUCodeTable
[ mineqindx
];
312 const char * GetAPDUCodeDescription ( uint8_t sw1
, uint8_t sw2
) {
313 const APDUCode
* cd
= GetAPDUCode ( sw1
, sw2
);
315 return cd
-> Description
;
317 return APDUCodeTable
[ 0 ]. Description
; //empty string